Format Interpreters
A format Interpreter is an advanced option that can alter the way a standard format is processed. These options should generally only be used after consultation with Patriot support staff.
There is an Interpreter option on each client available on the Event Types tab.
Interpreters Available
4X2 Binary
Contact ID Expanded
CID SIMMS II
CISSimmsIIByZone
Use Zone Group Code
Redirects a signal from one area of a client to another area depending on which area contains the reported zone. Behaves in a similar way to the Use Zone Group Code option (see Area Code section), but has the advantage of only being applied for certain event types. The Interpreter will only apply when the event type record uses an action plan of Zone Info, or when the event type action plan has User Info and the event type also has a module value above 0 set. To configure certain event types to ignore this Interpreter, ensure the action plan of the event type is of signal type User Info (Opening or Closing), and the event type has a module number value of 0.
Interpreter Overrides
This feature requires the Interpreter Overrides Module.
In addition to the default interpreter, you can add extra interpreters for specific signal format types. The interpreter will be used for the matching formats only - otherwise the existing/default interpreter will be used. Here is the list of signal formats that are currently supported:
-
Contact ID (CID)
-
Inner Range Fast (IRFast)
-
Four By Two
-
SIA
-
Ademco Fast (ADFast)
-
Manual*
*Applies to manually inserted signals
Note that Manual applies to manually inserted signals.